ABSTRACT: Only low enthalpy geothermal resources were bored in Slovakia up to the present time. That is the reason why the methodics of well tests, realized on geothermal wells, is based on methods of unsteady groundwater flow. For division of hydrodynamic tests graphic course drawn in semilogarithmic scale the linear model of regression analysis was used. The representative part for hydraulic parameters estimation is selected by the total logarithmic conversion difference. The hydraulic parameters estimation is shown on the example of geothermal well FGG-2 Galanta. Described methodics was used for programme JACOB creation.
bibliografický odkaz na článok:
Fendek, M. 1997: Metodika vyhodnocovania hydrodynamických skúšok pre geotermálne vrty.- Podzemná voda ISSN 1335-1052, III, 2/1997, 34-45.
geothermal well, geothermal water, unsteady groundwater flow, well test analysis, linear model of regression analysis, hydraulic parameters, tótal logarithmic conversion difference, skin effect